TAILIEUCHUNG - Biomedical Engineering Trends in Electronics Communications and Software Part 8

Tham khảo tài liệu 'biomedical engineering trends in electronics communications and software part 8', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 270 Biomedical Engineering Trends in Electronics Communications and Software The photodiode bias As discussed before the choice of the photodiode bias is a trade-off between the dark and the photogenerated currents. Moreover the measurement noise is highly related to the shot noise of the diode defined as I2Nolse 2 q Id a2 Hz 7 This implies a limit for the current to fill with the MDL of the system. In the experiments a reverse voltage sweep range from 0 V to -5 V was applied to the diode and has lead to choose a reverse bias of Vd to maximize the photocurrent under a constant A 280 nm illumination. It implies a dark current lDark of about 30 pA mm2 for the following experiment results. The optical dynamic OD is the value of the current of a blank sample reported to the dark current Bulteel et al. 2009 . When PCR tubes were used the current measured with a blank sample was of 3 nA. We then calculated that the OD was of 100 while it was of 700 with the quartz cuvettes. Results and discussion To validate the system two types of samples were tested and the results are reported in this section. Firstly pure genomic DNA Escherichia coli and secondly spores from bacteria Bacillus subtilis . Each substance was diluted into the microtubes to a volume of 50 yL corresponding to the same volume as in the quartz cuvettes and each tube was measured four times with the LEDs emitting at A 260 nm and A 280 nm. The repeated measurements are essential to take into account the tube displacements the heterogeneity of the solution each tube is periodically vortexed to re-homogenize the solution and other measurement discussed for the quartz calibration experiment since the lowest concentration provides the highest photocurrent all results are displayed as a percentage of the maximal measured current. This enables a normalization of the different tests over the optical dynamic. Measurement precision The precision of our system as introduced above in

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.