TAILIEUCHUNG - Biomedical Engineering Trends Research and Technologies Part 17

Tham khảo tài liệu 'biomedical engineering trends research and technologies part 17', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Critical Issues in Reprocessing Single-Use Medical Devices for Interventional Cardiology 629 Fig. 3. AFM on EP catheter shaft. Polyurethane underwent progressive nanometric roughening with repetitive gas plasma sterilization. Alterations were induced by the chemical and physical etching of the sterilization technique. From left to right and form top to bottom new device 1 4 8 cycles regenerated devices. Adapted from Tessarolo et al. 2004b. Functionality tests on EP catheters elicited no variations in ablation efficiency electrodes conductivity thermometric sensor s precision and accuracy Tessarolo et al. 2005 . Differently slipperiness tests showed a worsening of lubricious properties in regenerated EP devices after 4 cycles in accordance to the increase of surface roughness. Conversely functional properties of PTCA catheters were affected by both clinical use and reprocessing procedures Fig. 4 Fedel et al. 2006 . As a consequence of the mechanical stress in clinical use balloon diameter at nominal pressure tended to increase. Differently thermo-chemical stress due to cleaning and sterilization induced balloon shrinkage after the first reprocessing cycle. Subsequent cleaning and sterilization did not induce further dimensional alterations. However these modifications did not affect the performance of the device because compliance tests showed the conformity of reprocessed balloons within the 10 limit of acceptance of manufacturers original specifications. Anyway the authors suggested that in case of PTCA catheter reprocessing it would be profitable to introduce a new calibration curve with new nominal diameter values. Slipperiness and friction patterns were strictly dependent on PTCA device manufacturer and model but the magnitude of modifications did not compromise in-vitro catheters functionality up to three uses Fedel et al. 2006 . 630 Biomedical Engineering Trends Research and Technologies Fig. 4. Effects of cleaning and reprocessing on balloon working diameter

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.