TAILIEUCHUNG - INTERNATIONAL ENERGY CONSERVATION CODE phần 7

Khi nằm trong thiết bị. 2. Khi thiết kế sự khác biệt nhiệt độ giữa bên trong và bên ngoài của ống hoặc hội nghị trung ương không vượt quá 15 ° F (8 ° C). Tất cả các ống dẫn, xử lý không khí và hộp lọc sẽ được niêm phong. Khớp và đường nối được thực hiện theo mục 603,9 của Bộ luật Cơ khí quốc tế. | COMMERCIAL ENERGY EFFICIENCY 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1 200 cfm 600 Lis . Energy recovery ventilation systems. Individual fan systems that have both a design supply air capacity of 5 000 cfm m3 s or greater and a minimum outside air supply of 70 percent or greater of the design supply air quantity shall have an energy recovery system that provides a change in the enthalpy ofthe outdoor air supply of 50 percent or more of the difference between the outdoor air and return air at design conditions. Provision shall be made to bypass or control the energy recovery system to permit cooling with outdoor air where cooling with outdoor air is required. Exception An energy recovery ventilation system shall not be required in any of the following conditions 1. Where energy recovery systems are prohibited by the International Mechanical Code. 2. Laboratory fume hood systems that include at least one of the following features . Variable-air-volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50 percent or less of design values. . Direct makeup auxiliary air supply equal to at least 75 percent of the exhaust rate heated no warmer than 2 F below room setpoint cooled to no cooler than 3OF C above room setpoint no humidification added and no simultaneous heating and cooling used for dehumidification control. 3. Systems serving spaces that are not cooled and are heated to less than 60 F C . 4. Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. 5. Heating systems in climates with less than 3 600 HDD. 6. Cooling systems in climates with a I-percent cooling design wet-bulb temperature less than 64 F 18 C . 7. Systems requiring dehumidification that employ series-style energy recovery coils wrapped around the cooling coil. Duct and plenum insulation and sealing.

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.