TAILIEUCHUNG - INTERNATIONAL ENERGY CONSERVATION CODE phần 6

Bộ đèn Recessed cài đặt trong phong bì xây dựng nhiệt phải được niêm phong để hạn chế không khí rò rỉ giữa các điều kiện và vô điều kiện 4. Không gian nơi mà tỷ lệ luồng không khí cung cấp trừ đi bất kỳ yêu cầu trang điểm hoặc không khí chuyển đi ít hơn cfm (600 Lis). | COMMERCIAL ENERGY EFFICIENCY TABLE 2 BUILDING ENVELOPE REQUIREMENTS-OPAQUE ASSEMBLIES ROOFS DESCRIPTION REFERENCE R-19 Standing seam roof with single fiberglass insulation layer. This construction is R-19 faced fiberglass insulation batts draped perpendicular over the purlins. A minimum thermal spacer block is placed above the purlin batt and the roof deck is secured to the purlins. ASHRAE IESNA Table including Addendum G R-13 R-13 R-13 R-19 Standing seam roof with two fiberglass insulation layers. The first R-value is for faced fiberglass insulation batts draped over purlins. The second R-value is for unfaced fiberglass insulation batts installed parallel to the purlins. A minimum thermal spacer block is placed above the purlin batt and the roof deck is secured to the purlins. ASHRAE IESNA Table including Addendum G R-11 R-19 Fe Filled cavity fiberglass insulation. A continuous vapor barrier is installed below the purlins and uninterrupted by framing members. Both layers of uncompressed unfaced fiberglass insulation rest on top ofthe vapor barrier and are installed parallel between the purlins. A minimum thermal spacer block is placed above the purlin batt and the roof deck is secured to the purlins. ASHRAE IESNA Table including Addendum G WALLS R-16 R-19 Single fiberglass insulation layer. The construction is faced fiberglass insulation batts installed vertically and compressed between the metal wall panels and the steel framing. ASHRAE IESNA Table including Addendum G R-13 ci R-19 ci The first R-value is for faced fiberglass insulation batts installed perpendicular and compressed between the metal wall panels and the steel framing. The second rated R-value is for continuous rigid insulation installed between the metal wall panel and steel framing or on the interior of the steel framing. ASHRAE IESNA Table A3 .2 including Addendum G Slabs on grade. The minimum thermal .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.