TAILIEUCHUNG - Desiccant Enhanced Evaporative Air-Conditioning phần 5

Chi phí thương mại Bảng Hiệu suất 3-10 và 3-11 Bảng hiển thị các kết quả phân tích kinh tế cho tỷ lệ trả lại hoàn vốn hoặc IRR cho mỗi thành phố. Đánh giá từng là dựa trên một cuộc đời sản phẩm 15 năm cho mỗi hệ thống. Giá điện và khí đốt là số trung bình hàng tháng. Tỉ lệ thời gian sử dụng điện và tín dụng giảm cao điểm không được tính vào tài khoản. | Figure 3-26 LCC breakdown for retrofit for Phoenix hot dry and Houston hot humid loan is the repayment of the loan due to the upfront cost of each system Commercial Cost Performance Table 3-10 and Table 3-11 show the results of the economic analysis for the payback return rate or IRR for each city. Each rate is based on a 15-year product lifetime for each system. Rates for electricity and gas are monthly averages. Time-of-use electricity rates and peak reduction credit are not taken into account. Because A C power draw drives commercial peak consumption inclusion of these factors will increase electricity costs. This would inevitably improve the economics of the DEVap A C. Table 3-10 Economic Analysis for Houston Costs DX DEVap Difference First cost 15 200 20 461 35 Yearly electricity cost 2 676 173 -94 Yearly natural gas cost 0 874 Yearly water cost at 3 1000 gal 0 110 Net yearly cost 2 676 1 157 -57 IRR 28 Table 3-11 Economic Analysis for Phoenix Costs DX DEVap Difference First cost 15 200 20 461 35 Yearly electricity cost 2 646 164 -94 Yearly natural gas cost 0 157 Yearly water cost at 5 1000 gal 0 253 Net yearly cost 2 646 575 -78 IRR 39 41 Risk Assessment Technology Risks A C reliability generally means that commercial and residential A C equipment lifespan is expected to be 15 years and 11 years respectively DOE 2009 . Longevity of a new technology will always be in question especially compared to tried-and-true refrigeration-based A C. Answering all these concerns takes time although accelerated testing is being devised for DEVap. Longevity of the device would include issues such as Degradation of performance over the lifetime of the equipment Maintainability to sustain performance Catastrophic failure reducing the expected lifetime o Material degradation o Inadequate manufacturing techniques o Fundamental design issue. The DEVap A C will increase site water use by approximately 60 gal day for a typical home 3-ton air conditioner . This water use

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.