TAILIEUCHUNG - Báo cáo y học: "Effects on heart pumping function when using foam and gauze for negative pressure wound therapy of sternotomy wounds"

Tuyển tập các báo cáo nghiên cứu về y học được đăng trên tạp chí y học Wertheim cung cấp cho các bạn kiến thức về ngành y đề tài: Effects on heart pumping function when using foam and gauze for negative pressure wound therapy of sternotomy wounds. | Malmsjo et al. Journal of Cardiothoracic Surgery 2011 6 5 http content 6 1 5 JCTS JOURNAL OF CARDIOTHORACIC SURGERY RESEARCH ARTICLE Open Access Effects on heart pumping function when using foam and gauze for negative pressure wound therapy of sternotomy wounds Malin Malmsjo1 Sandra Lindstedt2 Richard Ingemansson2 Abstract Background Negative pressure wound therapy NPWT has remarkable effects on the healing of poststernotomy mediastinitis. Foam is presently the material of choice for NPWT in this indication. There is now increasing interest in using gauze as this has proven successful in the treatment of peripheral wounds. It is important to determine the effects of NPWT using gauze on heart pumping function before it can be used for deep sternotomy wounds. The aim was to examine the effects of NPWT when using gauze and foam on the heart pumping function during the treatment of a sternotomy wound. Methods Eight pigs underwent median sternotomy followed by NPWT at -40 -70 -120 and -160 mmHg using foam or gauze. The heart frequency cardiac output mean systemic arterial pressure mean pulmonary artery pressure central venous pressure and left atrial pressure were recorded. Results Cardiac output was not affected by NPWT using gauze or foam. Heart frequency decreased during NPWT when using foam but not gauze. Treatment with foam also lowered the central venous pressure and the left atrial pressure while gauze had no such effects. Mean systemic arterial pressure mean pulmonary artery pressure and systemic vascular resistance were not affected by NPWT. Similar haemodynamic effects were observed at all levels of negative pressure studied. Conclusions NPWT using foam results in decreased heart frequency and lower right and left atrial filling pressures. The use of gauze in NPWT did not affect the haemodynamic parameters studied. Gauze may thus provide an alternative to foam for NPWT of sternotomy wounds. Background Cardiac surgery is .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.