TAILIEUCHUNG - báo cáo hóa học: " Elimination kinetics of diisocyanates after specific inhalative challenges in humans: mass spectrometry analysis, as a basis for biomonitoring strategies"

Tuyển tập báo cáo các nghiên cứu khoa học quốc tế ngành hóa học dành cho các bạn yêu hóa học tham khảo đề tài: Elimination kinetics of diisocyanates after specific inhalative challenges in humans: mass spectrometry analysis, as a basis for biomonitoring strategies | Budnik et al. Journal of Occupational Medicine and Toxicology 2011 6 9 http content 6 1 9 _ JOURNAL OF OCCUPATIONAL MEDICINE AND TOXICOLOGY METHODOLOGY Open Access Elimination kinetics of diisocyanates after specific inhalative challenges in humans mass spectrometry analysis as a basis for biomonitoring strategies 1 2 3 4 1 Lygia T Budnik Dennis Nowak Rolf Merget Catherine Lemiere and Xaver Baur Abstract Background Isocyanates are some of the leading occupational causes of respiratory disorders predominantly asthma. Adequate exposure monitoring may recognize risk factors and help to prevent the onset or aggravation of these aliments. Though the biomonitoring appears to be most suitable for exposure assessment the sampling time is critical however. In order to settle the optimal time point for the sample collection in a practical biomonitoring approach we aimed to measure the elimination of isocyanate urine metabolites. Methods A simple biomonitoring method enabling detection of all major diamine metabolites from mono- poly-and diisocyanates in one analytical step has been established. Urine samples from 121 patients undergoing inhalative challenge tests with diisocyanates for diagnostic reasons were separated by gas chromatography and analyzed with mass spectrometry GC-MS at various time points 0-24 h after the onset of exposure. Results After controlled exposures to different concentrations of diisocyanates 496 102 ppb-min or 1560 420 ppb-min the elimination kinetics of respective isocyanate diamine metabolites revealed differences between aliphatic and aromatic isocyanates the latter exhibiting a slower elimination and a dose-response relationship. No significant differences were observed however when the elimination time patterns for individual isocyanates were compared in respect of either low or high exposure or in relation to the presence or absence of prior immunological sensitization. Conclusions The detection of isocyanate metabolites in

TÀI LIỆU LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.