TAILIEUCHUNG - Erection Bracing of Low-Rise Structural Steel Buildings phần 6

Vũ = (W) = (9,4) = 12,2 kips Kiểm tra kháng (4) 1. Thanh neo có đường kính. Vữa độ dày là 3. Thanh Neo có hạt hex san lấp mặt bằng nặng và 3 / 8. Máy giặt tấm. Các neo được cách nhau 10. Trung tâm và Gió dọc thành phần: 5,9 kips Net nén trên thanh neo: kips Sử dụng các yếu tố tải theo các Thông số kỹ thuật AISC LRFD: | Exposure Category B Bay Size ft. 50 Column Height ft. 15 Stories 1 Column Size W8X24 Base Plate Thickness in. Pier Size in. x in. 12X12 Footing Size ft. x ft. x in. Anchor Rods with Leveling Nuts Anchor Rod Diameter in. Anchor Pattern in. x in. 4X4 Hooked or Nutted 4 in. Hook Embedment in. 6 Cover Below Anchor in. 6 Anchor Rods Base Plate Shimmed or Grouted Anchor Rod Diameter in. Anchor Pattern in. x in. 4X4 Hooked or Nutted 3 in. Hook Embedment in. 6 Cover Below Anchor in. 3 Note Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases. Note Pier size given is the minimum size required for strength. A larger pier may be required to match the column provided. Note The anchor rod parameters given are minimums. Table Prescriptive Requirements for Exposure B 50 ft. Bays 15 ft. Column Height One Story Frame Exposure Category B Bay Size ft. 50 Column Height ft. 30 Stories 1 Column Size W8X31 Base Plate Thickness in. Pier Size in. x in. 18X18 Footing Size ft. x ft. x in. Anchor Rods with Leveling Nuts Anchor Rod Diameter in. Anchor Pattern in. x in. 4X4 Hooked or Nutted 4 in. Hook Embedment in. 9 Cover Below Anchor in. 9 Anchor Rods Base Plate Shimmed or Grouted Anchor Rod Diameter in. Anchor Pattern in. x in. 4X4 Hooked or Nutted 4 in. Hook Embedment in. 9 Cover Below Anchor in. 3 Note Footing thickness given is a minimum which must be increased to match embedment plus cover in some cases. Note Pier size given is the minimum size required for strength. A larger pier may be required to match the column provided. Note The anchor rod parameters given are minimums. Table Prescriptive Requirements for Exposure B 50 ft. Bays 30 ft. Column Height One Story Frame 2003 by American Institute of Steel Construction Inc. All rights reserved. This publication or any part thereof must not be reproduced in any form without permission of the publisher. Exposure Category B Bay .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.