TAILIEUCHUNG - Biosensors Emerging Materials and Applications Part 4

Tham khảo tài liệu 'biosensors emerging materials and applications part 4', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 112 Biosensors - Emerging Materials and Applications Fig. 8. Time trace of cantilever defections resulting from the binding of enantiomers of amino acids to micro cantilevers modified with covalently anti-L-amino acid antibody 1-4 or human immunoglobulin G 5 6 1-50 mg L L-tryptophan 2 5- 50mg L L-phenylalanine 3- 50 mg L D-tryptophan 4 6- 50 mg L D-phenylalanine. Dutta et al. 2003 . These antibodies have been also employed for enantioselective sequential-injection chemiluminescence immunoassay of triiodothhyronine and tetraiodothyronine with immunoreactor with immobilized haptens. It has been shown that the detection of of the L enantiomers in samples of D enantiomers is possible in less than 5 minutes including regeneration of immunoreactor Silvaieh et al. 2002 . Anti-D-AA was used in microfabricated cantilevers for enantioselective detection of amino acids based on inducing surface stress by intermolecular forces arising from analyte adsorption on surface-immobilized antibodies Dutta et al. 2003 . The temporal response of the cantilever allowed the quantitative determination of enantiomeric purity up to an enantiomeric excess of . Based on the slope of response curves or anti-D-amino acid antibody the selectivity coefficients for D- enantiomer towards L-isomer were and for D-phenylalanine D-tryptophan Fig 8. and D-methionine respectively. The largest enantioselectivity has been observed for D-valine 104 . 4. Enantioselective bioreceptors Mass-based biosensors There are many examples of sensors exhibiting the enantioselective properties based on quartz crystal microbalance technique for example sensor for L-histidine Zhang Z. et al. 2005 methyl lactate Ng et al. 2002 L-cysteine Chen Z. et al. 2000 L-phenylalanine Huang et al. 2003 or - menthol Tanese et al. 2004 . However the combination of biological macromolecules and QCM technique has been rarely reported for the studies of chiral discrimination. Two sensors were developed by .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.