TAILIEUCHUNG - Recent Advances in Mechatronics - Ryszard Jabonski et al (Eds) Episode 2 Part 6

Tham khảo tài liệu 'recent advances in mechatronics - ryszard jabonski et al (eds) episode 2 part 6', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 584 H. Urzẹdniczok 4. Two-parameter pressure and temperature measuring converter based on piezoresistive sensor The formulas 1 form a mathematical model of two-variable measuring converter of pressure and temperature to resistances R1 and R2 p ứ R1 R2 . By inverting these formulas is possible to determine the values of pressure and temperature if values of resistances R1 and R2 are known. The inverted model has following form ứ ứ p ứ p - p Ui - p ứ p 2 In this way a two-parameter two-dimensional 2D converter of sensors resistances to pressure and temperature R1 R2 p ứ may be realized. It is evident that a proper conditioning circuit and computation device are necessary as it is shown in Fig. 4. A conditioning circuit shown in Fig. 5 was applied. measured quantities Fig. 4. Structure of measuring chain of two-variable pressure and temperature converter based on piezoresistive sensor Fig. 5. Conditioning circuit based on NE555 oscillator a pulse output signal b Two-variable pressure and temperature measuring converter based on . 585 The output signal is a pulse signal and both of the two time intervals T1 and T2 depends on resistances R1 and R2 and in consequence on measured values p and A. As a computation device the ATmega8 microcontroller was applied to measure time intervals T1 and T2 and to calculate the measured values p and A . Equations 2 were used. 5. Conclusions The above described transducer was calibrated. In Fig. 6 the errors obtained for whole ranges of pressure kPa and temperature C are plotted. As it is visible maximum value of this errors not exceed C for temperature and kPa for pressure and in relation to the measuring range respectively . This value was obtained with assumption of first-order linear model of the transducer 1 . Applying second-order model allows errors decreasing but makes calculation more complicated. Instead above proposed global models 1 and 2 other method .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.