TAILIEUCHUNG - Bio-MEMS Technologies and Applications - Wang and Soper (Eds) Part 9

Tham khảo tài liệu 'bio-mems technologies and applications - wang and soper (eds) part 9', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Bio-MEMS Devices in Cell Manipulation 239 flow regime where the sample and sheath fluids rarely mix together. In this flow regime once the stream is stabilized the particle tends to stay on the same path in the fluidic channel. The flow in the channel is laminar when the Reynolds number Re is less than approximately 2300. The Reynolds number is defined as Re puD p where p u p and D are the density velocity dynamic viscosity of fluid and the diameter of the channel respectively. For example the density and the dynamic viscosity of water-based solutions are on the order of 103 kg m3 and 103 N-s m2 respectively. The diameter of the channel is often less than 500 pm in conventional cytometers. Therefore the flow in a cytometer is usually in the laminar regime unless the fluid velocity is faster than a few meters per second. Figure shows a flow of ink focused by sheath fluid in the laminar regime. It can be seen that the core and sheath fluids are clearly separated. In general flows in microfluidic devices are usually laminar flows in which mixing is limited by the slow nature of molecular diffusion. While there have been significant efforts to enhance mixing in microfluidic channels the slow mixing process in microchannels is a very attractive feature for cytometry applications. Moreover this feature allows one to integrate a sorting mechanism with a focusing channel because it is relatively easy to switch the flow direction without disturbing the particle streams as will be discussed in a subsequent section. Another key component of a flow cytometer is the optical system that excites fluorescently labeled particles and detects photons of selected wavelengths. The particle trajectory is coincident with the focus of one or more illumination sources and detectors that are used to determine the light scattering and fluorescence properties of individual particles. Because the fluorescence or scattering signal is much weaker than the excitation it is important to align

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.