TAILIEUCHUNG - Aeronautics and Astronautics Part 4

Tham khảo tài liệu 'aeronautics and astronautics part 4', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Numerical Investigation of Plasma Flows Inside Segmented Constrictor Type Arc-Heater 109 a Voltage b Mass-Averaged Enthalpy c Pressure d Efficiency Fig. 6. Comparison between Calculation and Experiment Figure 6 shows the results for I 2000 A. As shown in the figure the overall results show a tendency similar to the case of I 1600 A and are in good agreement with the experimental results. Considering the results described in Sections and we can say that the ARCFLO4 code predicted the arc heater flow accurately for high electric power cases. JAXA 750KW arc heater The Japan Aerospace Exploration Agency JAXA has serviced a 750 kW segmented arc heater since the 1990s and its operational data are available through the references of 110 Aeronautics and Astronautics Matsuzaki et al. 2002 and Sakai et al. 2007 . The JAXA 750 kW segmented arc heater operates at a current between 300 and 700 A and a mass flow rate between 10 and 20 g s. The constrictor length and diameter are 39 cm and cm respectively. The diameter of the nozzle throat is cm. The diameter and the radius of the electrode is cm and cm respectively. In this section a numerical flow calculation of the JAXA 750 kW arc heater is introduced as a low electric power case. The voltage between electrodes the mass-averaged enthalpy at the nozzle throat the pressure in the cathode chamber and the arc heater efficiency are calculated and compared to the experimental data. 35 30 25 20. 15. 10 5 a Voltage JAXA 750 kW Segmented Arc Heater I Experiments I 300A I Experiments I 500A k Experiments I 700A ---- ARCFLO4 I 300A ----ARCFLO4 I 500A ----ARCFLO4 I 700A 12 14 16 Mass flow rate g s 18 20 b Mass-Averaged Enthalpy c Pressure d Efficiency Fig. 7. Comparison between Calculation and Experiment Lee Kim 2010 Numerical Investigation of Plasma Flows Inside Segmented Constrictor Type Arc-Heater 111 Figure 7 shows a comparison of the operational data plotted in terms of mass flow rates. As shown in

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.