TAILIEUCHUNG - Power Quality Monitoring Analysis and Enhancement Part 12

Tham khảo tài liệu 'power quality monitoring analysis and enhancement part 12', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 262 Power Quality - Monitoring Analysis and Enhancement Has a low dependency of the THD on the high harmonic orders in the high modulation index. Reduces the size of the filter inductance Lf . This is because the order of the low order harmonic LOH increases Creates the minimum power and switching losses in the 50 and 100 modulation index interval respectively Produces the maximum number of levels in the line or phase voltage Provides rapid damping of the distortion factor DF of the line and the phase voltage versus the switching frequency. Because of this rapid damping DF is independent of the switching frequency Reduces the transient time for one cycle period to obtain a sinusoidal voltage and load current 263 Compensation of Reactive Power and Sag Voltage Using Superconducting Magnetic Energy Storage System Table 3. The implemented switching strategy in the three-level NPC inverter with Space Vector Pulse Width Modulation 3. A novel switching strategy for the two-quadrant three-level chopper As was previously discussed the SMES control methods for stabilizing capacitors voltage depends upon the power networks. In the first control approach the transmitted active and reactive power to the network is controlled by a NPC voltage source inverter while the capacitors voltage is stabilized using a chopper. This approach is used to investigate the interaction between the SMES and the power networks. This control approach is easily implemented if an optimized and appropriate switching strategy for the chopper is defined 5 shows a two-quadrant three-level chopper that was studied in this work. In Table 4 all possible switching states in the three-level chopper as well as the SMES coil current path are provided. One of the main requirements for the switching strategy of the multi-level choppers is to minimize both the switching losses and the frequency in order to eliminate the need for high frequency electronic switches. Moreover minimization of the power loss is .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.