TAILIEUCHUNG - Wide Spectra of Quality Control Part 6

Tham khảo tài liệu 'wide spectra of quality control part 6', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 140 Wide Spectra of Quality Control x-ray film is the detector with limited capacity of data collection for which significantly important is the proper optimization of process of image development starting with proper device setting exposure management through the process of photographic proceeding system sensitivity artefacts in image level of noises illumination conditions of dark room to proper choice of parameters of the whole imaging system intensifying screens in range of length of emitted light relevant to parameters of applied x-ray films . Properly setting of elements of diagnostic data development reflects creating the most beneficial conditions for proper image quality optimization . In analog systems quality and diagnostic evaluation takes place in descriptive rooms with use of viewing box which should absolutely meet parameters values determining respectively the illumination conditions no more than 50 lx as well as lumination of emitted light cd m2 . B. Systems CR An imaging detector in digitized computed radiography CR is phosphor imaging plate. An essential detection component of its structure is a layer of luminophore PSP-photostimulable phosphor imaging system Fig. 8 . source http page Fig. 8. Construction of CR imaging plate protective layer phosphor layer base absorbing light layer protective layer label of code The imaging plate is placed in the cassette similar to one used for analog radiography. Geometry and imaging technique are similar as well. In the system basing on phosphorous imaging plates x-ray radiation quanta are absorbed by a phosphor layer of the imaging plate IP . Deposited energy of x-ray radiation in the material of the imaging plates is stored in a portion of energy located in metastable regions called F-centres. During x-ray beam exposure the latent image is formed in phosphor layer by accumulation of energy in these centres. Reading of imaging information from CR plates bases on the phenomenon of .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.