TAILIEUCHUNG - Advances in Optical and Photonic Devices 2011 Part 15

Tham khảo tài liệu 'advances in optical and photonic devices 2011 part 15', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Ultra-Sensitive Optical Atomic Magnetometers and Their Applications 339 following wavelengths of the pump and probe lasers will be needed 700 nm for K 795 nm for Rb for Cs with some tuning range nm allowed for optimization. Many diode lasers of these wavelengths are available making an AM a quite inexpensive device easy to operate. In addition to the wavelength selection the requirement for power is also important to consider. For relatively small cells employed in single-channel magnetometers the power on the order of 50 mW is sufficient. The pump power requirements can be simply estimated from the analysis of the magnetometer sensitivity as the function of the pumping rate. For example the signal of the SERF magnetometer scales as R R RSD 2 it is directly proportional to polarization level which is the ratio R R RSD and inversely to magnetic resonance width or R RSD and hence the optimal value of the pumping rate is R RSD . If the pumping rate is below this value the signal linearly decreases and so SNR if it is limited by technical probe beam noise see below which is often the case. The pumping rate is related to the pumping power. If we assume that photons are required for pumping one atom see previous discussion for a cell containing N atoms the power needed to achieve a given pumping rate R is P . For the specific case R RSD for a typical spindestruction rate of 45 s-1 see Alred et al 2002 in a cell containing N 8 X1014 atoms P 14 mW. Various losses including the reflection by the cell walls and optics and some pumping efficiency factors would set the requirement above 20 mW for the considered case. If we have the power below this value the magnetometer signal will be below optimal value. Here is one reason that lamps which for a needed band have power below 1 mW are not optimal for pumping SERF magnetometers. In some applications the bandwidth has to be increased so even higher pump power will be needed. To have some room for .

TÀI LIỆU LIÊN QUAN
69    272    11
TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.