TAILIEUCHUNG - CONTROL PANEL DESIGN

panel manufacturing facility caters for panels ranging from Form 1 to Form 4 including panels for use in hazardous areas. The panels are built from approved electrical panel design drawings, which detail all components in a parts list, cable schedules and sizes, terminal numbers, etc. All the drawings are produced using AutoCAD and are capable of being emailed in PDF or original format. A dimensional drawing of the internal and external panel enclosure with any display or identification labels, lights, etc., will be fully detailed | CONTROL PANEL DESIGN Our panel manufacturing facility caters for panels ranging from Form 1 to Form 4 including panels for use in hazardous areas. The panels are built from approved electrical panel design drawings which detail all components in a parts list cable schedules and sizes terminal numbers etc. All the drawings are produced using AutoCAD and are capable of being emailed in PDF or original format. A dimensional drawing of the internal and external panel enclosure with any display or identification labels lights etc. will be fully detailed. When appropriate the panel will include for the customers Free Issue control equipment and customers logo and drawing label identification or serial numbers. The panel design manufacturing and testing procedures are fully covered to BS EN ISO 9000 2000. RACE Integrated can provide a complete range of the following types of control panel enclosures. INTERNAL FORM OF SEPARATION IEC 60439-1 1999 Annex D gives the following guidelines for the different separation types. One of more of the following conditions can be obtained by dividing ASSEMBLIES by mean of partitions or barriers metallic or non-metallic into separate compartment or enclosed protected spaces Protection against contact with hazardous parts belonging to the adjacent functional units. The degree of protection shall be at least IPXXB. Protection against the passage of solid foreign bodies from one unit of an ASSEMBLY to an adjacent unit. The degree of protection shall be at least IP2X. Unless otherwise stated by the manufacturer both conditions shall apply. NOTE The degree of protection IP2X covers the degree of protection IPXXB The following are typical forms of separation by partitions 1 FORM 1 No separation FORM 2A Separation of busbars from the functional units. The terminals for external conductors do not need to be separated from the busbars. FORM 2B Separation of busbars from the functional units. The terminals for external conductors are separated from

TỪ KHÓA LIÊN QUAN
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.