TAILIEUCHUNG - Air Pollution Control Systems for Boiler and Incinerators Part 9

Tham khảo tài liệu 'air pollution control systems for boiler and incinerators part 9', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | TM 5-815-1 AFR 19-6 1 ABSC B R 9 catalytic reduction section 2 SURGE TANK IO cooler 3 REGENERATION SECTION 1 1 SULPHUR holding pit 4 DISSC-VING tank 12 1 3 C-A JS CONVERTER 5 concentrated so discharge 14 15 CONDENSORS 6 PREHEATER 16 coalescer 7 natural gas addition 17 INC INERAT0R 8 HEATER . Army Corps of Engineers Figure 10 3. Wellman-Lord S02 reduction system to attrition chemical decomposition serious corrosion problems and danger of combustion of the reactivated carbon. 2 Zeolites are a class of highly structured aluminum silicate compounds. Because of the regular pore size of zeolites molecules of less than a certain critical size may be incorporated into the structure while those greater are excluded. It is often possible to specify a certain zeolite for the separation of a particular material. Zeolites possesses properties of attrition resistance temperature stability inertness to regeneration techniques and uniform pore size which make them ideal absorbents. However they lack the ability to catalyze the oxidation of SO2 toSO3 and thus cannot desulfurize flue-gases at normal operating temperatures. Promising research is under way on the development of a zeolite material that will absorb SO2 at flue-gas temperatures by oxidation of SO3 and subsequently store it as a sulphate in the pores of the zeolite. v. Cost of flue-gas desulfurization. The actual capital and operating costs for any specific installation are a function of a number of factors quite specific to the plant and include Plant size age configuration and locations Sulfur content of the fuel and emission control requirements Local construction costs plant labor costs and cost for chemicals water waste disposal etc. Type of FGD system and required equipment Whether simultaneous particulate emission reduction is required. 10-3. Procedure to minimize SOX emission a. Efficiency requirement. The SOx removal efficiency necessary for any given installation is dependent upon the strictest regulation .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.