TAILIEUCHUNG - Handbook of Advanced Interventional Cardiology - part 8

Khó khăn trong việc thúc đẩy ống thông qua guidewire. (A) ống thông hình thành một vòng lặp trong động mạch chủ. (B) đỉnh của ống thông flips trở lại vào động mạch chủ. (Trích từ Gerlock AJ, Mirfakhraee M. Khó khăn trong việc đặt ống thông nội bộ và bên ngoài động mạch cảnh trong | 456 Practical Handbook of Advanced Interventional Cardiology Figure 22-14 Difficulty in advancing the catheter over the guidewire. A The catheter forms a loop in the aorta. B The tip of the catheter flips back into the aorta. Adapted from Gerlock AJ Mirfakhraee M. Difficulty in catheterization of the internal and external carotid arteries. In Gerlock AJ Mirfa-khraee M eds. Essentials of Diagnostic and Interventional Angiographic Techniques. WB Saunders 1985. With permission from the publisher. Table 22-6 Mechanisms of failure in advancing the catheter 1. The wire is not strong enough to support the catheter. 2. The angle of the origin of the carotid artery is too acute. 3. Too much friction exists between the guidewire and the internal surface of the catheter. 4. The curve of the distal end of the catheter prevents further advancement. To solve the problem of a weak platform created by a floppy wire mechanism 1 the wire has to be advanced further so the stiff segment is in the proper area. If the wire is not strong enough it has to be exchanged to a stiffer To solve the problem of acute angle at the origin of the artery mechanism 2 a stiff wire will straighten out the angle and help to advance the wire. To solve the problem created by mechanism 3 due to excessive friction between the wire and the internal surface of the catheter the catheter should be advanced and the guidewire withdrawn Carotid Artery Interventions 457 Figure 22-15 Diagram showing how to reduce the friction between the wire and the internal surface of the catheter. A The catheter tip is at the orifice of the left CCA and the tip of the wire is in the left ICA. B The catheter is advanced while the wire is withdrawn. Adapted from Gerlock AJ Mirfakhraee M. Difficulty in catheterization of the internal and external carotid arteries. In Gerlock AJ Mirfakhraee M eds. Essentials of Diagnostic and Interventional Angiographic Techniques. WB Saunders 1985. With permission from the publisher. .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.