TAILIEUCHUNG - Solid State Circuits Technologies Part 15

Tham khảo tài liệu 'solid state circuits technologies part 15', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Ppt-level Detection of Aqueous Benzene with a Portable Sensor based on Bubbling Extraction and UV Spectroscopy 411 4. Portable aqueous benzene characterization Sensitivity Experiments were first performed with a 5-min concentration time and aqueous benzene concentration varying within the low ppbV range. To assess the improvement in terms of sensitivity we plot in Fig. 11 the benzene peak absorption amplitude as function of aqueous benzene concentration for the two experimental set-ups . with and without the concentration stage. First the concentration stage doesn t deteriorate the sensor s response which remains linear in both cases with a comparable slope. For both set-ups the linear range may extend for concentrations higher than those shown in Fig. 11. However the lack of experimental data at higher concentration levels does not allow us to assess the linear range upper limit with certainty. Furthermore the use of the concentration stage leads to an overall shift of the response of about more than 2 orders of magnitude towards the low concentration levels. This huge improvement yields a detection limit of about 300 pptV which is five hundred times below the previously reported LOD and more than ten times below the regulatory levels in both Japan and America 11 and 5 ppbV respectively . In summary the concentration cell leads to subsequent sensitivity improvement that enables us to clear the drinking water regulatory levels while the response remains linear over more than two orders of magnitude. Furthermore due to the 5-min concentration time one measurement takes less than ten minutes including all the steps required to calibrate the spectrophotometer. Fig. 11. Aqueous benzene sensor response around the ppbV benzene concentration range with blue squares and without red diamonds the concentration stage. 412 Solid State Circuits Technologies Concentration time The previous results were all otained with a 5-min concentration time which provides enough

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.