TAILIEUCHUNG - Voltage Sags and Interruptions

causing a voltage sag with duration of more than 1 cycle occurs within the area of vulnerability. However, faults outside this area will not cause the voltage to drop below pu. The same discussion applies to the area of vulnerability for ASD loads. The less sensitive the equipment, the smaller the area of vulnerability will be (and the fewer times sags will cause the equipment to misoperate). The voltage sag performance for a given customer facility will depend on whether the customer is supplied from the transmission system or from the distribution system. For a customer supplied from the transmission. | Simpo PDF Merge and Split Unregistered Version - http Voltage Sags and Interruptions Simpo PDF Merge and Split UnregisVeiredlVef causing a voltage sag with duration of more than 1 cycle occurs within the area of vulnerability. However faults outside this area will not cause the voltage to drop below pu. The same discussion applies to the area of vulnerability for ASD loads. The less sensitive the equipment the smaller the area of vulnerability will be and the fewer times sags will cause the equipment to misoperate . Transmission system sag performance evaluation The voltage sag performance for a given customer facility will depend on whether the customer is supplied from the transmission system or from the distribution system. For a customer supplied from the transmission system the voltage sag performance will depend on only the transmission system fault performance. On the other hand for a customer supplied from the distribution system the voltage sag performance will depend on the fault performance on both the transmission and distribution systems. This section discusses procedures to estimate the transmission system contribution to the overall voltage sag performance at a facility. Section focuses on the distribution system contribution to the overall voltage sag performance. Transmission line faults and the subsequent opening of the protective devices rarely cause an interruption for any customer because of the interconnected nature of most modern-day transmission networks. These faults do however cause voltage sags. Depending on the equipment sensitivity the unit may trip off resulting in substantial monetary losses. The ability to estimate the expected voltage sags at an end-user location is therefore very important. Most utilities have detailed short-circuit models of the interconnected transmission system available for programs such as ASPEN One Liner Fig. . These programs can calculate .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.