TAILIEUCHUNG - Inspection Evaluation And Repair Of Steel structures Part 13

Tham khảo tài liệu 'inspection evaluation and repair of steel structures part 13', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | EM 1110-2-6054 1 Dec 01 Figure 8-12. Cracked girder tension flange at diaphragm of a lift gate 3 Repair alternatives. a The ideal crack repair would also improve the fatigue strength of the detail and would eliminate the out-of-plane distortion. However to eliminate the displacement shown in Figure 3-5 would require significant structural modification and the cracking might not have occurred given connection details with higher fatigue strength. The fatigue strength of the detail would be improved by providing a smooth radius between the diaphragm flange and girder flange. This would improve the stress concentration condition and could theoretically improve the fatigue strength from Category E to Category B see condition 16 of Table 2-1 . The recommended repair is a combination of crack repair procedures shown in Figures 8-3 and 8-4. First repair the crack according to Figure 8-4 while following the guidelines for welded crack repair given in paragraph 8 -4a. Then add the radius plate and drill the hole as shown in Figure 8-3 and as described in paragraph 8-6a 3 . b Another possible alternative would be to install a bolted repair similar to that shown in Figure 8-7 a similar repair is described in paragraph 8-6c 3 . Before the bolted repair is installed the crack tip should be drilled and the diaphragm-flange-to-girder-flange weld should be removed to eliminate the stress concentration. c In the design of new gates the low fatigue strength details could be eliminated by installing a skin plate on the downstream face of the gate. This was done in a recent design of a vertical lift gate. Instead of downstream bracing members the new design called for a skin plate on the downstream face of the gate. g. Crack in vertical lift gate at uncoped web stiffener. 1 Description of condition. A through-thickness crack that extends through the tension flange of a built-up girder on a vertical lift gate is shown in Figure 8-13. The structure had been in service for less than 2 .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.