TAILIEUCHUNG - IMechatronic Systems, Applications Edited by Annalisa Part 8

Tham khảo tài liệu 'imechatronic systems, applications edited by annalisa part 8', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 134 Mechatronic Systems Applications hip joint moments calculated by using the two systems is being of the maximal magnitude of the hip joint moments. a _. _ b _ c Fig. 16. Joint moments estimated by the wearable sensor systems solid line and the force plate Hi-DCam camera systems dashed line . Ankle plantarflexor knee extensor and hip flexor are positive and ankle dorsiflexion knee flexor and hip extensor are negative. a Ankle joint moments. b Knee joint moments. c Hip joint moments. 6. Conclusion A new wearable sensor system was developed for measuring tri-directional ground reaction force GRF and segment orientations. A stationary force plate can not measure more than one stride moreover in studies of stair ascent and descent measurements a complex system consisting of many stationary force plates and a data fusion method must be constructed Stacoff et al. 2005 Della and Bonato 2007 . The wearable sensor system proposed in this chapter can be applied to successive walking trials in a number of non-laboratory environments because of its lower-cost small size and lower effects on human movements. The joint moment estimations of the ankle knee and hip joints using the measurements of the wearable sensor system is an application study. The joint moment data should be helpful for understanding the cause of certain gait abnormalities and the motion mechanism of human walking when we combine it with the other measurements such as 3D joint angles and electromyography. In the verification experiments we measured the triaxial GRF coordinates of CoP and lower limbs angular displacements and caluculated joint moments using the measurments of the wearable sensor system and the force plate optical camera system. The analysis of the RMS differences between the two systems was implemented and the results of the RMS differences demonstrated that the force and motion measurement results and the joint moment estimation results have high consistence between the

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.