TAILIEUCHUNG - Seamanship Techniques 2011 E Part 13

Tham khảo tài liệu 'seamanship techniques 2011 e part 13', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | Fire-Fighting 183 INTERNATIONAL SHORE CONNECTION This is a fitment which is normally carried by all ships in order to provide a common link between shore hydrants and ships fire mains Figure . It is employed either aboard the vessel itself or ashore in conjunction with local fire brigade tenders in the event of fire breaking out while the vessel is in port. The shore connection is usually situated in such a position as to be easily accessible to Fire Brigade officers near the top of accommodation ladders or mate s office. Indicator plate 114 mm Blank flange Blank is drilled for four bolts. The hose flange has four bolts and four slots for the shore hose if required. 115 mm mm Brass keep chain Figure International shore connection. 305 mm SELF-CONTAINED BREATHING APPARATUS The Siebe Gorman International Mk II self-contained breathing apparatus Figure employs two cylinders of compressed air which the wearer exhales direct to atmosphere. The cylinders are of a lightweight design so that when fully charged the apparatus complete with mask weighs only 38 lb. 17 kgs . The cylinder volume is 4 litres providing enough air for 20 minutes when the wearer is engaged on hard work. Both cylinders have the same capacity. The amount of work carried out by the wearer will obviously affect the consumption of air and consequently the time that person may continue working. The following are guidelines supplied by the manufacturer Hard work rate 40 minutes twin cylinders . Moderate work rate 62 minutes. At rest 83 minutes. Pre-operational Checks monthly 1. Ensure that by-pass control is fully closed. 2. Open cylinder valves. The whistle if fitted will be momentarily heard as pressure rises in the set. Check cylinders are fully charged. 184 Seamanship Techniques Pressure guage tube Pressure guage Cylinder Warning whistle Emergency by-pass cOntrol Harness Demand valve Auxiliary air C line adapter Pressure Cylinder gauge shut off Back plate valve Warning whistle .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.