TAILIEUCHUNG - Refrigeration and Air Conditioning 3 Episode 13

Tham khảo tài liệu 'refrigeration and air conditioning 3 episode 13', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 354 Refrigeration and Air-Conditioning 1. Incorrect setting of head pressure controls 2. Dirty or choked spray nozzles in water tower or evaporative condenser so that the surface is not fully wetted 3. Non-condensible gas in circuit 4. Bad location of condensers so that air recirculates 5. Undersized condensers 6. Dirty fins on air-cooled condensers 7. Fans not working or broken 8. Water strainers blocked 9. Undersize pumps fitted 10. Air in water circuit While all these factors affect the good running of positive-displacement compressors the effect is far worse with centrifugal machines which can approach stall condition and so give a much reduced cooling duty. Maintenance The good running order of equipment depends on the standards of maintenance. This is a running cost to be assessed with all the others. If it is found to be faulty the investigation must consider what this is costing in terms of plant inefficiency and the expenditure to reach acceptable standards. This might be in the replacement or extra training of staff or in contracting the work out. If the latter the cost must include super visor y expenses. Remedial action on existing equipment The faults described above are largely self-revealing and most of them can be corrected or improved without a great deal of expenditure. The presence of separate metering devices should give an immediate indication of the savings made. Improved controls and equipment on existing plant Deficiencies on the original plant might be corrected by comparatively minor improvements changes and additions. Each should be assessed for its individual contribution to energy economy and how it may improve the per formance of other parts of the system. 1. Optimum-start controls. 2. Ambient-biased set point controls. Efficiency and economy in operation 355 3. Modifications to give improved air and water flows where these were shown to be deficient . increase fan speeds change fans change pumps improve ductwork or .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.