Tham khảo tài liệu 'refrigeration and air conditioning 3 episode 12', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 31 Control systems Function The purpose of a control system on a refrigeration or air-conditioning plant is to 1. Provide automatic operation . avoid the cost of attendant labour or for where control is too complex for manual operation 2. Maintain the controlled conditions closer than could be achieved by manual operation 3. Provide maximum efficiency and economy of operation 4. Ensure safe operation at all times The control system will consist of a loop with detector sensor controller and controlled device. The communication between these parts of the loop will be electric pneumatic or mechanical see Figure 62 . Detector sensor Controller Figure Basic control loop Detectors sensors Types of detector are two-position on-off and proportional. The Control systems 325 two-position will be set to actuate at upper and lower limits and will respond when its sensitive element reaches these set limits. Since all devices have some time lag in operation the controlled condition will overshoot to some extent depending on the time lag of the detector and the extent to which the rate of supply of energy to the process exceeds the load. See Figure . The range of the control will therefore be the differential of the detector plus the upper and lower overshoots under load. Figure Limits of controlled variable with two-position control. a Capacity closely matched to load b Capacity much greater than load Two-position detectors such as thermostats can be fitted with an anticipatory bias to reduce the amount of overshoot. In such instruments a small bias heater accelerates the action of the control. An alternative method to reduce overshoot is to introduce a timing device so that it acts intermittently. Where the two-position sensor is also the controller it provides only two plant outputs maximum or zero. A two-position detector can be used to operate a floating control. At the upper limit it will operate the control in one direction and if it reaches

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.