TAILIEUCHUNG - Refrigeration and Air Conditioning 3E Episode 4

Tham khảo tài liệu 'refrigeration and air conditioning 3e episode 4', kỹ thuật - công nghệ, cơ khí - chế tạo máy phục vụ nhu cầu học tập, nghiên cứu và làm việc hiệu quả | 84 Refrigeration and Air-Conditioning Refrigerant liquid level Fluid inside _ s T tubes V boooj pSppot jo o_cxXcfoopo oooooooooop oooppppdo . toooooooppdpy X o o00000000 Voo ooooooozz o o o o_0o z a b Refrigerant liquid level Fluid level in tank- Refrigerant liquid level c Figure Flooded evaporators. a Shell-and-tube. b Jacketted. c Raceway etc. will have finned pipe coils see Figure . In all but very small coolers there will be fans to blow the air over the coil. Construction materials will be the same as for air-cooled condensers. Aluminium fins on copper tube are the most common for the halocarbons with stainless steel or aluminium tube for ammonia. Frost or condensed water will form on the fin surface and must be drained away. To permit this fins will be vertical and the air flow horizontal with a drain tray provided under. The size of the tube will be such that the velocity of the boiling fluid within it will cause turbulence to promote heat transfer. Tube diameters will vary from 9 mm to 32 mm according to the size of coil. Fin spacing will be a compromise between compactness and cost and the tendency for the interfin spaces to block with condensed moisture or frost. Spacings will vary from 2 mm on a compact airconditioner to 12 mm on a low-temperature coldroom coil 8 . Liquid cooling evaporators Liquid cooling is mostly in shell-and-tube or shell-and-coil evaporators. In the shell-and-tube type the liquid is usually in the pipes and the shell is some three-quarters full of the liquid boiling refrigerant. A number of tubes is omitted at the top of the shell to give space for the suction gas to escape clear of the surface without entraining Evaporators 85 Figure Air cooling evaporators. a Floor mounted. b Ceiling mounted Courtesy of Searle Manufacturing Co. liquid. Further features such as multiple outlet headers suction trap domes and baffles will help to avoid liquid droplets entering the main suction pipe. Gas velocities should not exceed 3

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.