TAILIEUCHUNG - Advanced Application 2- Completed state and construction stage analyses of a suspension Bridge

Within half a century, a new branch of mathematics mathematical theory of planning-formed and flourished due to economic urgently required to implement the optimal targets: most, least, the fastest, cheapest, best, . today, the rapid development of electronic computer engineering have made it possible to practice for design automation in many areas. Such as determining the parameters of the optimal building structure standard cheapest price, calculate the tension adjustment of the cable-stayed bridge to the red sphere deviation versus the smallest sphere desired, select size cross-sectional size of structural parts that meet the testing standards and the smallest volume of. | Advanced Application 3 Completed State and Construction stage Analyses of a Suspension Bridge Bridge Dimensions Spans L 650 m Bridge width B m 10@ 125 m 32@ 400 m 10@ 125 m X ầ Civil 2006 - D HOC PHAN MEMWAS CML 03-Suspension Bridge - Model View - 5 X File Edit View Model Load Analysis Results Design Mode Query Tools Window Help Freque. Grid S. 1 UCS GCS1 View c. Actrat. Wizard Node Element Property 1 BC Mass Stage Load Moving 1 Settlem. 1 Result 1 Influenc. Query s12131 V t 1 H Base T 1 Ễ 1 5 y 1 11 OAi Tree Menu ụ X Menu I Tables Group I Works Structure Anaf sis I2i Configuration ỆỊ Geometry Static Loads Response Spectrum Analysis -V Time History Analysis Ệ Moving Load Analysis T Settlement Analysis Data Ỹ7 Composite Section Analysis Data I2i Heat of Hydration Analysis Data 2 Non-Linear Analysis Data Hi Construction Stage Analysis Data n Results Jljj Design Unit System -Length------ m c on c mm c ft r in -Force Mass -r N kg f kN ton r kgf kg Í tonf ton r Ibf lb c kjps krps g Temperature Í Celsius Ĩ Fahrenheit l X -Heat c cal c kcal c kJ Btu Open a new file ũ New Project save as Suspension Bridge .mcb Save and assign a unit system. Note Selected units are displayed in relevant dialog boxes. Values are NOT changed with units. I- Set change Default Unit System OK Apply Cancel File D New Project File s Save Suspension Bridge Tools Unit System alternatively select from the status bar at the bottom of the screen Length m Force tonf J_ r J Message Window ậ X A T El Qt 4 T 1 1 1 Command Message Ậ Analysis Message lb V For Help press Fl None U 0 0 0 G 0 0 0 tonf v m v - t nonfv 9 I 1 2

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.