TAILIEUCHUNG - Fiber Optic Cable Armored In/Outdoor Dry Loose Tube Cables: Riser

ADC’s innovative line of indoor/outdoor armored loose tube cables are designed to meet all the rigors of the outside plant environment and have the necessary fire ratings to be installed inside the building. These cables eliminate the messy gel filler of traditional loose tube style cables with super absorbent polymers. The installer can place the cable anywhere in the network, bypassing the traditional transition points required in most installations. Cables are available with fiber counts from 2 to 144 fibers | Fiber Optic Cable Armored In Outdoor Dry Loose Tube Cables Riser SPEC SHEET ADC s innovative line of indoor outdoor armored loose tube cables are designed to meet all the rigors of the outside plant environment and have the necessary fire ratings to be installed inside the building. These cables eliminate the messy gel filler of traditional loose tube style cables with super absorbent polymers. The installer can place the cable anywhere in the network bypassing the traditional transition points required in most installations. Cables are available with fiber counts from 2 to 144 fibers. Features No cleaning of gels greatly reduces installation time Reduces labor costs by eliminating transition points at the demarcation Can be used outdoors or indoors in riser areas Applications Between buildings in a campus environment Riser rated environments Outside plant environments Compliances Telcordia GR-20-CORE Telcordia GR-409-CORE EIA TIA FOTPs ETL UL 1666 NEC OFCR FT-4 ISO IEC 11801 EIA TIA 568B 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Fiber Optic Cable Armored In Outdoor Dry Loose Tube Cables Riser Specifications Armored In Outdoor DLT Cables Riser 12 FIBER CABLE 250 pm UV Colored Optical Fiber mm Thermoplastic Tube Drygel Water Blocked Strength Member Interlocking Aluminum Armor Flame Retardant Inner and Outer Jackets ENVIRONMENTAL CHARACTERISTICS oo 72 FIBER CABLE Storage Temperature -40 to 85 C -40 to 185 F Operating Temperature -40 to 75 C -40 to 167 F Installation Temperature -20 to 60 C -4 to 140 F MECHANICAL CHARACTERISTICS 250 pm UV Colored Optical Fiber mm Thermoplastic Tube Drygel Water Blocked Strength Member Central Strength Member Interlocking Aluminum Armor Flame Retardant Inner and Outer Jackets Diameter mm in Maximum Tensile Load N Ibf Short Term install 1335 300 2670 600 2670 600 Long Term 400 90 200 890 200 890 Minimum Bend Radius cm in Short Term install

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.