TAILIEUCHUNG - Fiber Optic Cable Furcation Tubing

Features: • Multitude of sizes to fit your specific applications • Various colors for easy circuit identification • Variety of materials – choose one suited to YOUR requirements • Minimal shrinkage materials are available • Available for use in extreme environments • Non Out-Gassing versions available Applications: • Patching active devices • Terminating Loose Tube Cables • Manufacturing your own cabling with specialty fibers • Fortifying distribution cables for patch cable applications • Buffering bare fibers in coupler and splitter applications • Manufacturing Breakout (Fanout) Kits • Medical devices. | Fiber Optic Cable Furcation Tubing ADC s furcation tubes provide factory-standard guaranteed performance specifications. They are 100 dimensionally tested and are offered in a variety of materials. SPEC SHEET Features Multitude of sizes to fit your specific applications Various colors for easy circuit identification Variety of materials - choose one suited to YOUR requirements Minimal shrinkage materials are available Available for use in extreme environments Non Out-Gassing versions available Applications Patching active devices Terminating Loose Tube Cables Manufacturing your own cabling with specialty fibers Fortifying distribution cables for patch cable applications Buffering bare fibers in coupler and splitter applications Manufacturing Breakout Fanout Kits Medical devices 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Fiber Optic Cable Furcation Tubing Specifications Furcation Tubing Furcation Tubing Environmental Characteristics Storage Temperature -55 to 85 C -67 to 185 F Operating Temperature -40 to 85 C -40 to 185 F Installation Temperature -40 to 85 C -40 to 185 F Mechanical Characteristics Test Procedure Units Results Crush Resistance EIA-FOTP-41A N cm 1200 Impact Resistance EIA-FOTP-25B of impacts 500 Flexing of Cycles EIA-FOTP-104A of cycles 10 000 Maximum Pulling Load EIA-FOTP-33A N lb 2000 1 12 Maximum Operating Load EIA-FOTP-33A N lb 1000 67 Min. Bend Radius @ Max Load EIA-FOTP-33A 15 x Cable OD Low Temperature Bend Test EIA-FOTP-37A C F Passed @ -40 -40 1-952-938-8080 -800-366-3891 Fiber Optic Cable Furcation Tubing Ordering Information Furcation Tubing Standard Products Description Catalog Number 500 X 900 pm PVC furcation tubing - available in 12 colors F6NPVCFT5X9YY 500 x 900 pm Hytrel furcation tubing - available in 12 colors for extreme temperatures and chemical resistance F7NHYTFT5X9YY 500 x 900 pm PVDF furcation tubing - available in 12 colors for low shrink requirements material meets UL 94 V-0 .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.