TAILIEUCHUNG - TrueNet® CopperTen® Termination Block

The 20-pair TrueNet® CopperTen® termination block is designed to suit five incoming and five outgoing four-pair Category 6a cables. Each IDC slot is color-coded to allow for accurate termination of each of the four pairs. The CopperTen termination block utilizes a disconnect feature making it ideal for Patch-by-Exception installations and can also be patched as a traditional cross-connect. The cable manager at the rear of the module ensures that cables are held in place securely without the need for Velcro ties | TrueNet CopperTen Termination Block SPEC SHEET The 20-pair TrueNet CopperTen termination block is designed to suit five incoming and five outgoing four-pair Category 6a cables. Each IDC slot is color-coded to allow for accurate termination of each of the four pairs. The CopperTen termination block utilizes a disconnect feature making it ideal for Patch-by-Exception installations and can also be patched as a traditional cross-connect. The cable manager at the rear of the module ensures that cables are held in place securely without the need for Velcro ties. Features Transmission performance to component compliance as well as 10 Gigabit ISO IEC 11801 extrapolated component Color-coded for ease of termination Each module will accommodate five four-pair UTP CopperTen cables 45-degree silver-plated IDCs provide secure reliable gas-tight connections Blocks can be terminated with standard termination tool or with a 110 tool Four-pair to four-pair patch cords are available for Patch-by-Exception installations Four-pair to RJ45 cords are available to interface with network and other equipment 1 -952-938-8080 1 -800-366-3891 111 111 CISCOPARTNER Technology Developer El TrueNet CopperTen Termination Block TrueNet CopperTen Termination Block Specifications MECHANICAL Wire range for solid and stranded copper conductors Wire insulation diameter range PE PVC Number of wire terminations Wire insertion force mm conductor diameter Wire pull out force radial mm conductor diameter Wire pull out force axial mm conductor diameter Number of patching cycles ELECTRICAL Transmission performance and reliability Voltage current rating at 25 C 77 F ambient Insulation resistance ENVIRONMENTAL AND SAFETY Safety compliance Flammability rating of plastic housing Environment for use mm to mm 26 to 22 AWG mm to mm 100 6 N 5 N 35 N Modules up to 750 Patch Plugs up to 200 standards 150 VAC at max 50 000 M at 500 VDC UL

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.