TAILIEUCHUNG - Fiber Optic Cable Simplex and Duplex Loose Tube Cables

ADC's loose tube simplex and duplex cables provide factory standard guaranteed performance specifications. They are 100% optically tested and are offered with a variety of optical performance levels. Features: • Extremely light weight • Exstremely small outer diameter • UV stabilized polyethylene jacket • Easier to install than conventional loose tube cables • Eliminates the need for large cable trailers Applications: • Crowded ducts • Along or inside chain link fencing • Small conduit. | Fiber Optic Cable Simplex and Duplex Loose Tube Cables SPEC SHEET ADC s loose tube simplex and duplex cables provide factory standard guaranteed performance specifications. They are 100 optically tested and are offered with a variety of optical performance levels. Features Extremely light weight Exstremely small outer diameter UV stabilized polyethylene jacket Easier to install than conventional loose tube cables Eliminates the need for large cable trailers Applications Crowded ducts Along or inside chain link fencing Small conduit 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1 Fiber Optic Cable Simplex and Duplex Loose Tube Cables Specifications Simplex Duplex Loose Tube Cables 2 Fiber Cable Polyurethane Outer Jacket Aramid Yarn Strength Member O mm Gel Filled Loose Tube PX 245 Acrylate Coated Fiber Environmental Characteristics Storage Temperature -40 to 85 C -67 to 185 F Operating Temperature -40 to 70 C -40 to 158 F Installation Temperature -20 to 70 C -40 to 158 F Mechanical Characteristics Test Procedure Units Results Crush Resistance EIA-FOTP-41A N cm 900 Impact Resistance EIA-FOTP-25B of impacts 100 Flexing of Cycles EIA-FOTP-104A of cycles 1 000 Maximum Pulling Load EIA-FOTP-33A N lb 400 112 Maximum Operating Load EIA-FOTP-33A N lb 100 67 Maximum Vertical Rise EIA-FOTP-33A m ft 30 98 Min. Bend Radius @ Max Load EIA-FOTP-33A cm in 1-952-938-8080 1-800-366-3891 Fiber Optic Cable Simplex and Duplex Loose Tube Cables Simplex Duplex Loose Tube Cables Construction Characteristics Strand Count Cable Diameter mm in 1 Fiber 2 Fiber v y Optical Performance Multimode Fiber Maximum Attenuation @ 850 1300 nm Typical Attenuation @ 850 1300 nm Minimum Bandwidth @ 850 1300 nm Core Diameter pm Clad Diameter pm Coat Diameter pm Numerical Aperture 50 125 500 500 50 3 125 2 500 25 25 200 500 3 125 2 245 10 100 140 100 100 100 3 140

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.