TAILIEUCHUNG - Lưu lượng kế hơi nước kiểu Vortex

The SPIRAX SARCO Steam Meter consists of four basic parts. 1. M111 Transducer. This is installed in the steam line at the point where the steam flow is to be measured. (See TIS ). It is supplied complete with a 2m length of 8 core heat resistant cable for connection to the M322 Conditioning Unit. 2. EL2600 Pressure Transmitter. This provides a 4-20 mA analogue signal to the M322 Conditioning Unit proportional to line pressure for superheated steam applications (see TIS ). 3. M322 Conditioning Unit | Section Flowmetering Spiraflo flowmeters Gilflo flowmeters Vortex flowmeters Orifice plate flowmeters Computers displays and transmitters Flowmetering spir arco TI-P330-02 MI Issue 1 Spring Loaded Variable Area Steam Meter Description The SPIRAX SARCO Steam Meter consists of four basic parts. 1. M111 Transducer. This is installed in the steam line at the point where the steam flow is to be measured. See TIS . It is supplied complete with a 2m length of 8 core heat resistant cable for connection to the M322 Conditioning Unit. 2. EL2600 Pressure Transmitter. This provides a 4-20 mA analogue signal to the M322 Conditioning Unit proportional to line pressure for superheated steam applications see TIS . 3. M322 Conditioning Unit. The function of this unit is to accept flow rate and temperature signals from the M111 Transducer and pressure signals from the EL2600 Pressure Transmitter and convert them to digital form for transmission to the M210G Computer. 4. M210G Flow Computer. This accepts signals from the M322 Conditioning Unit processes and displays them. The keypad enables the user to select the parameters to be viewed as well as allowing access to the numerous facilities available. See TIS . Note Wiring between Computer EL2600 Pressure Transmitter and Conditioning Unit to be provided by user installer. The SPIRAX SARCO Steam Meter is designed for use on dry saturated and superheated steam only. Flow rates are based on a max. flow velocity of 35m s. Correct installation is important if accurate and reliable flow metering is to be achieved. Full Installation Instructions are supplied with each unit. Basic essentials of good installation are shown overleaf. Commissioning and Operating Instructions are also available for each unit. Performance_ Accuracy _ 2 of measured flow 1 of FSD at 50 flow Repeatability Turndown .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.