TAILIEUCHUNG - Automating Manufacturing Systems with PLCs P2

In ladder logic there are multiple types of outputs, but these are not consistently available on all PLCs. Some of the outputs will be externally connected to devices outside the PLC, but it is also possible to use internal memory locations in the PLC. Six types of outputs are shown in Figure . The first is a normal output, when energized the output will turn on, and energize an output. The circle with a diagonal line through is a normally on output. When energized the output will turn off. This type of output is not available on all PLC types | plc wiring - Ladder Logic Outputs In ladder logic there are multiple types of outputs but these are not consistently available on all PLCs. Some of the outputs will be externally connected to devices outside the PLC but it is also possible to use internal memory locations in the PLC. Six types of outputs are shown in Figure . The first is a normal output when energized the output will turn on and energize an output. The circle with a diagonal line through is a normally on output. When energized the output will turn off. This type of output is not available on all PLC types. When initially energized the OSR One Shot Relay instruction will turn on for one scan but then be off for all scans after until it is turned off. The L latch and U unlatch instructions can be used to lock outputs on. When an L output is energized the output will turn on indefinitely even when the output coil is deenergized. The output can only be turned off using a U output. The last instruction is the IOT Immediate OutpuT that will allow outputs to be updated without having to wait for the ladder logic scan to be completed. When power is applied on the output x is activated for the left output but turned off for the output on the right. x An input transition on will cause the output x to go on for one scan this is also known as a one shot relay @x __ plc wiring - When the L coil is energized x will be toggled on it will stay on until the U coil is energized. This is like a flip-flop and stays set even when the PLC is turned off. x x L x L x x U U Some PLCs will allow immediate outputs that do not wait for the program scan to end before setting an output. Note This instruction will only update the outputs using the output table other instruction must change the individual outputs. IOT IOT x Note Outputs are also commonly shown using parentheses - - instead of the circle. This is because many of the programming systems are text based and circles cannot be drawn. Figure .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.