TAILIEUCHUNG - Measurement of power consumption parameters in the presence of high harmonics

The paper presents the study of high harmonics influence on power metering by static meters for active and reactive energy. The review and analysis of manufacturer’s documents and standards in the field of electricity meters testing was conducted and mathematical models for calculating active and reactive energy were identified. | Measurement of power consumption parameters in the presence of high harmonics International Journal of Mechanical Engineering and Technology IJMET Volume 10 Issue 03 March 2019 pp. 1204 1209 Article ID IJMET_10_04_122 Available online at http ijmet JType IJMET amp VType 10 amp IType 3 ISSN Print 0976-6340 and ISSN Online 0976-6359 IAEME Publication Scopus Indexed MEASUREMENT OF POWER CONSUMPTION PARAMETERS IN THE PRESENCE OF HIGH HARMONICS Shklyarskiy . Skamyin . Vasilkov Chair of General Electrotechnic Saint-Petersburg Mining University St. Petersburg Russia ABSTRACT The paper presents the study of high harmonics influence on power metering by static meters for active and reactive energy. The review and analysis of manufacturer s documents and standards in the field of electricity meters testing was conducted and mathematical models for calculating active and reactive energy were identified. Various electronic meters were tested at the experimental stand. As a result the errors of active and reactive energy metering in the presence of high harmonics were determined. It is shown that the implemented in static meters equations for the active and reactive energy calculation can lead to unfair payments for electrical energy in the presence of high harmonics. Key words Power consumption reactive energy THD mathematical model harmonic distortion active power reactive power Cite this Article Shklyarskiy . Skamyin . Vasilkov Measurement of Power Consumption Parameters in the Presence of High Harmonics International Journal of Mechanical Engineering and Technology 10 3 2019 pp. 1204 1209. http IJMET JType IJMET amp VType 10 amp IType 3 1. INTRODUCTION Reorganization of Russian electrical energy structure which was finished at 2008 led to the separation of vertically integrated companies into independent generating grid companies power sales companies and operational dispatch control subjects. So since

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.