TAILIEUCHUNG - Optimum seismic design of tuned story mass damper using multi objective genetic algorithm

The results showthat considering the TSMD systemon the fifth floor leads to the most reduction in displacement and velocity, not only for the roof, but also for the other floors as well. For the system under study, comparing with the noncontrolled system, a reduction of about 31% on maximumdisplacement and 42% on maximum velocity of the top floor are obtained. | JSEE Vol. 18, No. 4, 2016 Technical Note Optimum Seismic Design of Tuned Story Mass Damper Using Multi-Objective Genetic Algorithm Mohammad Vahid Azadpour 1, Abdolreza Zare2*, and Hamid Rahmani 3 1. . Student, Department of Civil Engineering, University of Yasouj, Yasouj, Iran 2. Assistant Professor, Department of Civil Engineering, University of Yasouj, Yasouj, Iran, * Corresponding Author; email: zare@ 3. Assistant Professor, Department of Civil Engineering, University of Zanjan, Zanjan, Iran Received: 05/10/2015 Accepted: 21/01/2017 AB S T RA CT Keywords: Optimization; Seismic response; Genetic Algorithm; Tuned Story Mass Damper A new system called Tuned Story Mass Damper (TSMD) is proposed and modified to enhance the seismic performance of mid-rise buildings. In TSMD systems, some part of a story's mass is utilized as Mass Damper, and an external passive damping device is used to provide the expected control force. For an 11-story structural model under seismic excitations, the equations of motion are solved in state space and two objective functions, the maximum displacement and maximum velocity of the top floor are considered to be minimized simultaneously. Using a fast and elitist Non-dominated Sorting Genetic Algorithm (NSGA-II) approach, the optimum design parameters of the TSMD system, including mass, stiffness and damping as well as the best location of the TSMD system among the floors of the structure are obtained. The results show that considering the TSMD system on the fifth floor leads to the most reduction in displacement and velocity, not only for the roof, but also for the other floors as well. For the system under study, comparing with the noncontrolled system, a reduction of about 31% on maximum displacement and 42% on maximum velocity of the top floor are obtained. 1. Introduction Tuned mass damper (TMD) is one of the most reliable control devices that have been used to attenuate vibration of different structures .

TỪ KHÓA LIÊN QUAN
TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.