TAILIEUCHUNG - Grid retaining control of wind power plants system using doubly fed induction generators by passivity - based method

The surveying and evaluation of the quality of control method for wind power systems using Doubly-Fed Induction Generators (DFIG) is a highly important signification. A new designing methodology for the passivity-based nonlinear controller is applied to gain some results which are described in this paper as can be seen, to control the Doubly-Fed Induction Generators, to maintain grid retaining of system in syschronical fault case which lead to drop a part of grid voltage. | Cao Tiến Huỳnh và Đtg Tạp chí KHOA HỌC & CÔNG NGHỆ 128(14): 149 - 154 GRID RETAINING CONTROL OF WIND POWER PLANTS SYSTEM USING DOUBLY-FED INDUCTION GENERATORS BY PASSIVITY -BASED METHOD Dang Danh Hoang* College of Technology - TNU SUMMARY The surveying and evaluation of the quality of control method for wind power systems using Doubly-Fed Induction Generators (DFIG) is a highly important signification. A new designing methodology for the passivity-based nonlinear controller is applied to gain some results which are described in this paper as can be seen, to control the Doubly-Fed Induction Generators, to maintain grid retaining of system in syschronical fault case which lead to drop a part of grid voltage Key word: Passivity - based control , wind power, grid fault. Notation Notation R(x) J(x) Unit G(x) Lr T r, T s H s r, rad/s sd, sq Wb rd, rq Wb Lm H Meaning Attenuation matrix Matrix links blocks in system structure. Matrix represents input, output relation. Rotor’s induction. Timing constant of rotor and stator Rotor’s radian frequency, mechanical angular speed of rotor Components d and q of magnetic flux stator Components d and q of magnetic flux rotor Summing dissipated coefficient. Mutual inductance between stator and rotor Abbreviation DFIG PĐSG EL Doubly-Fed Induction Generators Wind power generators. Euler - Lagrange PBC NL Passive based control Energy PREFACE* Recently, in our country as well as in over the world, controlling Doubly-Fed Induction Generators in Wind power generators system (PĐSG) is a considerative problem. Now, there are some researchers who using a few control methods, such as: accurate * Tel: 0912 847588 156 linearazation[9], backstepping[1] and had gotten positive results. We ourselves also published searching projects in this field [2, 3]. This article introduces achievement of passivity-based control method to control Doubly-Fed Induction Generators in the case of grid failure. In details: Control .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.