TAILIEUCHUNG - Technical Seminar Effective solutions for motor starting and protection

 Technical Seminar Effective solutions for motor starting and protection presents about IEC Standard and Motor Starting Methods; effective solutions for motor starting and protection motor protection agenda; motor protection manual motor starters ms132 rated ultimate short circuit breaking capacity; main electrical parameters of motors and somethings else.    | ABB Low Voltage Products HCMC Technical Seminar Effective solutions for motor starting and protection ABB Group April Slide 1 Effective solutions for motor starting and protection Agenda 9 00 -9 15 welcome and safety briefing 9 15 -10 00 IEC Standard and Motor Starting Methods 10 00 -10 15 coffee break 10 15 -11 00 Softstarter - PSTX 11 00 -11 15 coffer break 11 15 -12 00 Contactor - AF Technology 12 00 -12 15 Q A ABB Group April 17. 2015 Slide 2 H nil M IP IEC Standard Motor Starting Methods ABB Group April Slide 3 Motor Protection Rated short-circuit breaking capacities Rated short-circuit breaking capacities are defined in the IEC 60947-2 Low-voltage switchgear and controlgear -part 2 Circuit-breakers The rated short-circuit breaking capacities are stated as rated ultimate short-circuit breaking capacity Icu rated seivice short-circuit breaking capacity Ics ABB Group April Slide 4 H Illi 1 Motor Protection Rated ultimate short-circuit breaking capacity Icu Manual Motor Starters MS132 Short-circuit protection - Ratings I_________I The rated ultimate short-circuit breaking capacity of a Manual Motor Starter is the value of the short-circuit current the Manual Motor Starter is able to break twice according to the sequence of O -1 - CO cycle at the corresponding rated operating voltage. The Manual Motor Starter not required to carry its rated current after the opening and closing cycle. Ics Rated service short-circuit breaking capacity Example 25A 400V required rating 50kA à no backup fuse required until 50kA short circuit withstand 25A 400V required rating 60kA à backup fuse must be 100A AEE-Group_____ April 17 2015 1 Slide 5 nr ABEIGroup April 17 2015 1 Slide 7 AIỈIỈ Motor Protection Rated service short-circuit breaking capacity Ics I I Test of rated service short-circuit breaking capacity The sequence of operations shall be O -1 - CO -1 - CO The rated service short-circuit breaking capacity of a Manual Motor Starter is the current value .

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.