TAILIEUCHUNG - Tissue harmonic imaging with coded excitationa

It becomes more important to obtain medical ultrasound images with higher signal-to-noise ratio (SNR) and higher spatial resolution. In the last decade, tissue harmonic imaging (THI) and coded excitation to medical ultrasound imaging have been investigated. | 6 Tissue Harmonic Imaging with Coded Excitation Masayuki Tanabe1 2 Takuya Yamamura2 Kan Okubo2 and Norio Tagawa2 1JSPS Research Fellow 2Graduate School of System Design Tokyo Metropolitan University Japan 1. Introduction It becomes more important to obtain medical ultrasound images with higher signal-to-noise ratio SNR and higher spatial resolution. In the last decade tissue harmonic imaging THI and coded excitation to medical ultrasound imaging have been investigated. Coded excitation can overcome the trade-off between spatial resolution and penetration which occurs when using the conventional pulse Chiao 2005 Hu et al. 2001 Tanabe et al. 2008 . It is said that chirp signal is the most robust code for medical ultrasound image Misaridis Jensen 2005 . THI can acquire higher spatial resolution image and has been used in the commercial medical ultrasound system. A combination of coded excitation and THI coded THI has been investigated Arshadi et al. 2007 Hu et al. 2001 Song et al. 2010 Tanabe et al. 2010 . As a problem of THI the frequency bandwidths of the fundamental and the harmonic components often overlap. The spectral overlap causes degradation of spatial resolution and the undesirable artifact. For the solution to the problem only the harmonic component is extracted by pulse inversion PI method. However if reflectors in the region of interest ROI move even a little the fundamental components of echos are not cancelled completely. The intensity of the extracted harmonic components is still much smaller than the intensity of the residual fundamental component. Hence the residual fundamental component has a bad effect on THI. In sections II through IV THI coded excitation and the combination of them are explained. In section V we propose a new method which can extract broader bandwidth of the harmonic component for coded THI. The feasibility of the method is evaluated with experiments and simulations and the expected performance in term of axial resolution and SNR

TAILIEUCHUNG - Chia sẻ tài liệu không giới hạn
Địa chỉ : 444 Hoang Hoa Tham, Hanoi, Viet Nam
Website : tailieuchung.com
Email : tailieuchung20@gmail.com
Tailieuchung.com là thư viện tài liệu trực tuyến, nơi chia sẽ trao đổi hàng triệu tài liệu như luận văn đồ án, sách, giáo trình, đề thi.
Chúng tôi không chịu trách nhiệm liên quan đến các vấn đề bản quyền nội dung tài liệu được thành viên tự nguyện đăng tải lên, nếu phát hiện thấy tài liệu xấu hoặc tài liệu có bản quyền xin hãy email cho chúng tôi.
Đã phát hiện trình chặn quảng cáo AdBlock
Trang web này phụ thuộc vào doanh thu từ số lần hiển thị quảng cáo để tồn tại. Vui lòng tắt trình chặn quảng cáo của bạn hoặc tạm dừng tính năng chặn quảng cáo cho trang web này.